11kV Distribution & Power Transformers — 11kV Transformer Manufacturer | Oil-Immersed & Dry-Type Distribution Transformers

Voltage Class — 11 kV (11,000 V)

11kV Distribution & Power Transformers

11 kV is the dominant medium-voltage distribution standard across Sub-Saharan Africa, Southeast Asia, South Asia, and the Middle East. XinHuan manufactures IEC 60076 oil-immersed and cast resin dry-type transformers at 11 kV nominal primary voltage (stepping down to 400 V / 415 V), from 50 kVA to 2500 kVA.

50–2500
kVA range
11 / 0.4 kV
rated voltage
IEC 60076
certified
24h
quote response

Product Range

11kV Distribution & Power Transformers — 175 Models Available

Standard and custom capacities available for global utility, industrial, and commercial projects. View complete catalog →

Technical Overview

11kV to 400V / 415V — Global Utility & Industrial Standard

11 kV (11,000 V nominal, 12 kV highest system voltage Um, 75 kV BIL lightning impulse withstand) is the primary medium-voltage distribution class deployed across IEC utility grids in Africa, the UK, India, Pakistan, Bangladesh, Malaysia, Myanmar, and GCC nations. Standard distribution configurations step 11 kV down to 400 V or 415 V three-phase (230 V / 240 V single-phase) with a Dyn11 vector group.

XinHuan manufactures both hermetically sealed corrugated-tank oil-immersed transformers (S11, S13, S20, and amorphous alloy SBH15) and epoxy cast-resin dry-type transformers (SCB13, SCB14, Class F/H insulation) at 11 kV. Every unit features high-permeability grain-oriented silicon steel laminations, electrolytic copper or aluminum windings, and ±2 × 2.5% off-circuit tap changers (or OLTC on request).

Every 11 kV transformer undergoes 100% routine Factory Acceptance Testing (FAT) in our Hefei high-voltage laboratory per IEC 60076-1 and IEC 60076-3: winding resistance, voltage ratio and vector group verification, short-circuit impedance and load loss (Pk), no-load loss and current (Po / Io), power-frequency AC withstand (28 kV HV / 3 kV LV), and induced overvoltage withstand.

11kV Distribution & Power Transformers — Key Specifications

  • Rated Primary Voltage

    11 kV (10.5 kV / 11 kV / 11.5 kV configurable)

  • Rated Secondary Voltage

    0.4 kV (400 V / 415 V / 433 V three-phase)

  • Insulation Level (LI / AC)

    75 kV peak lightning impulse / 28 kV 1-min power frequency (Um = 12 kV)

  • Capacity Range

    50 kVA – 2500 kVA distribution; up to 31.5 MVA power class

  • Construction Types

    Oil-Immersed (ONAN/ONAF) & Cast Resin Dry-Type (AN/AF) & Pad-Mounted

  • Vector Group & Taps

    Dyn11 (standard) or Yyn0; ±2 × 2.5% or ±4 × 2.5% OCTC

  • Short-Circuit Impedance

    4.0% (50–630 kVA) / 4.5%–5.0% (800–1000 kVA) / 6.0% (1250–2500 kVA)

  • Applicable Standards

    IEC 60076-1, IEC 60076-11, GB/T 1094, BS EN 50588, SANS 780

IEC / IEEE Reference Data

11kV Distribution & Power Transformers — Standard Capacity & Loss Parameters

Request Custom Datasheet
11kV Distribution & Power Transformers — Standard Capacity (kVA), No-Load Loss (P0), Load Loss (Pk), Impedance (Uk%), and Weight Specification Table
Rated Capacity Voltage Ratio (HV / LV) No-Load Loss (P0) Load Loss (Pk) Impedance (Uk%) No-Load Current (I0%) Approx. Total Weight
50 kVA 11 / 0.4 kV 105 W 870 W 4.0% 1.4% 420 kg
100 kVA 11 / 0.4 kV 170 W 1,500 W 4.0% 1.2% 640 kg
200 kVA 11 / 0.4 kV 290 W 2,600 W 4.0% 1.0% 960 kg
315 kVA 11 / 0.4 kV 410 W 3,650 W 4.0% 0.9% 1,280 kg
500 kVA 11 / 0.4 kV 590 W 5,150 W 4.0% 0.8% 1,750 kg
630 kVA 11 / 0.4 kV 710 W 6,200 W 4.5% 0.7% 2,080 kg
800 kVA 11 / 0.4 kV 860 W 7,500 W 5.0% 0.7% 2,480 kg
1000 kVA 11 / 0.4 kV 1,030 W 9,000 W 5.0% 0.6% 2,920 kg
1250 kVA 11 / 0.4 kV 1,220 W 11,000 W 5.5% 0.6% 3,520 kg
1600 kVA 11 / 0.4 kV 1,480 W 13,500 W 6.0% 0.5% 4,260 kg
2000 kVA 11 / 0.4 kV 1,810 W 16,200 W 6.0% 0.5% 5,150 kg
2500 kVA 11 / 0.4 kV 2,150 W 19,500 W 6.0% 0.4% 6,180 kg

Guaranteed parameters based on standard factory testing. Custom loss levels (Tier-2 Ecodesign, DOE 2016, and high-efficiency low-noise designs) are engineered on request.

11kV Distribution & Power Transformers — 3D Engineering Anatomy Cutaway

High-precision 3D component breakdown of 11kV Distribution & Power Transformers illustrating CRGO silicon steel core assembly, electrolytic copper windings, insulation, and protection accessories.

11kV Distribution & Power Transformers internal 3D cutaway showing silicon steel core, copper windings, and tap changer
11kV Distribution & Power Transformers — Internal Core, Winding & Dielectric Assembly
High-Grade Silicon Core
Electrolytic Copper Coil
Off-Circuit / OLTC Tap Switch
Buchholz & Temp Relays

11kV Distribution & Power Transformers — Factory Acceptance Testing (FAT)

Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.

100% full routine tests (IEC 60076) conducted before export packing.

Engineering Submittal & Layout Workbench

Substation Room Fit & Multi-Equipment CAD Footprints

Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.

Available Ratings:
IEC 60076-1 Submittal Specs
XinHuan Engineering GA CAD Drawing
XinHuan Engineering Single Line Diagram (SLD)
11kV / 33kV Dual Voltage
IEC 60076 / IEEE Compliant
100% Routine Factory Tested
Export Nitrogen / Seaworthy Pack

1000 kVA Technical Dimensions

IEC 60076-1

International utility & industrial submittal specifications

Overall Length (L) 1,750 mm
Overall Width (W) 1,120 mm
Overall Height (H) 1,780 mm
Roller Wheel Track Gauge (D) 820 mm
Total Equipment Net Weight 3,820 kg
Min Substation Clearance 1,000 mm surrounding
Rated Voltage / System 11 kV / 33 kV Dual Primary
Applicable Standard IEC 60076-1 / IEEE C57
Download Technical Data Sheet (PDF) Request Factory Engineering Submittal Package

Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.

Quality & Compliance

Certified B2B Manufacturing & Laboratory Performance

Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.

IAF / CNAS Accredited

ISO 9001:2015 Quality System

Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.

Environmental System

ISO 14001:2015 Environmental

Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.

Occupational Health

ISO 45001:2018 Safety System

Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.

CNAS Lab Type Tests

IEC 60076 & GB Type Tests

Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.

SGS Audited Supplier

SGS Verified Manufacturer Audit

On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.

≥180 Units/Yr Export

International Delivery Certificate

Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).

Technical Q&A

Frequently Asked Questions — 11kV Distribution & Power Transformers

An 11kV transformer is a medium-voltage power or distribution transformer rated for an 11,000V nominal primary network (Um = 12kV, 75kV BIL). It steps voltage down to 400V or 415V three-phase for utility substations, industrial plants, commercial complexes, mining camps, and solar step-up stations.

Yes. We manufacture 11kV/400V, 11kV/415V, and 11kV/433V no-load secondary ratios according to local utility regulations, complete with ±2×2.5% or ±5% off-circuit tap changers to compensate for feeder voltage drop.

11kV oil-immersed transformers (S13/S20) offer lower initial cost, compact outdoor footprint, and higher overload tolerance for outdoor pole-mount or pad/substation installations. 11kV cast resin dry-type transformers (SCB13/SCB14) are flame-retardant, self-extinguishing (F1/C2/E2), and maintenance-free, making them mandatory for indoor basements, hospitals, high-rise buildings, and data centers.

Dyn11 uses a Delta (D) primary winding that traps 3rd-order harmonic currents circulating in the loop, paired with a grounded Star (yn) secondary that provides a stable 4-wire neutral for single-phase 230V/240V loads and earth-fault protection.

Every unit undergoes 100% IEC 60076-1 routine testing in our Hefei laboratory: DC winding resistance, voltage ratio and phase displacement check, short-circuit impedance and load loss measurement, no-load loss and excitation current measurement, 28kV AC separate-source dielectric withstand, and 2×Un induced overvoltage test. Full certified FAT reports accompany every shipment.

Copper windings offer higher thermal conductivity, smaller physical footprint, and superior short-circuit mechanical withstand. Aluminum windings reduce upfront transformer procurement cost by 15-22% while matching identical electrical efficiency and temperature rise guarantees through larger conductor cross-sections.

Standard production lead time is 2 to 3 weeks for standard distribution capacities (50kVA–1600kVA). Ocean shipping from Shanghai/Ningbo port takes approximately 22–32 days to Lagos (Nigeria), Mombasa (Kenya), Tema (Ghana), Durban (South Africa), and 15–20 days to Jebel Ali (UAE) and Dammam (Saudi Arabia).

Please provide: rated capacity (kVA), HV/LV voltage ratio (e.g., 11kV / 0.415kV), construction type (oil-immersed or dry-type), winding material (copper or aluminum), frequency (50Hz or 60Hz), quantity, and destination port for a firm EXW, FOB, or CIF quote within 24 hours.

Engineering Reference Silo

Transformer Category Pillars & International Standards

China Transformer Manufacturer Export Hub

11kV Distribution & Power Transformers — Direct Factory Quotation

Request Engineering Submittals & Price

Include capacity (kVA), primary voltage (11 kV), secondary voltage (400V/415V), standard (IEC/GB), destination port, and required quantity. Our engineers respond with certified data sheets within 24 hours.