50 kVA 33kV Three-Phase Oil-Immersed Distribution Transformer
This 50 kVA oil-immersed distribution transformer is designed for reliable power...
Voltage Class — 11 kV (11,000 V)
11 kV is the dominant medium-voltage distribution standard across Sub-Saharan Africa, Southeast Asia, South Asia, and the Middle East. XinHuan manufactures IEC 60076 oil-immersed and cast resin dry-type transformers at 11 kV nominal primary voltage (stepping down to 400 V / 415 V), from 50 kVA to 2500 kVA.
Product Range
Standard and custom capacities available for global utility, industrial, and commercial projects. View complete catalog →
This 50 kVA oil-immersed distribution transformer is designed for reliable power...
630 kVA K-13 dry-type transformer engineered specifically for large motor drive...
This 630 kva three-phase european type compact substation is an integrated...
This 2000 kva three-phase k-factor isolation oil transformer is configured for a...
This indoor high voltage electrical control cabinet is designed for...
This 75 kVA oil-immersed distribution transformer is designed for dependable...
500 kVA / K-13 cast resin dry-type transformer engineered for high-density...
This 500 kva three-phase european type compact substation is an integrated...
This 1000 kva three-phase k-factor isolation oil transformer is configured for a...
This kyn28 three-phase high voltage switchgear panel is designed for...
This 75 kVA oil-immersed distribution transformer is designed for dependable...
315 kVA K-13 cast resin distribution transformer designed for mining processing...
Technical Overview
11 kV (11,000 V nominal, 12 kV highest system voltage Um, 75 kV BIL lightning impulse withstand) is the primary medium-voltage distribution class deployed across IEC utility grids in Africa, the UK, India, Pakistan, Bangladesh, Malaysia, Myanmar, and GCC nations. Standard distribution configurations step 11 kV down to 400 V or 415 V three-phase (230 V / 240 V single-phase) with a Dyn11 vector group.
XinHuan manufactures both hermetically sealed corrugated-tank oil-immersed transformers (S11, S13, S20, and amorphous alloy SBH15) and epoxy cast-resin dry-type transformers (SCB13, SCB14, Class F/H insulation) at 11 kV. Every unit features high-permeability grain-oriented silicon steel laminations, electrolytic copper or aluminum windings, and ±2 × 2.5% off-circuit tap changers (or OLTC on request).
Every 11 kV transformer undergoes 100% routine Factory Acceptance Testing (FAT) in our Hefei high-voltage laboratory per IEC 60076-1 and IEC 60076-3: winding resistance, voltage ratio and vector group verification, short-circuit impedance and load loss (Pk), no-load loss and current (Po / Io), power-frequency AC withstand (28 kV HV / 3 kV LV), and induced overvoltage withstand.
Rated Primary Voltage
11 kV (10.5 kV / 11 kV / 11.5 kV configurable)
Rated Secondary Voltage
0.4 kV (400 V / 415 V / 433 V three-phase)
Insulation Level (LI / AC)
75 kV peak lightning impulse / 28 kV 1-min power frequency (Um = 12 kV)
Capacity Range
50 kVA – 2500 kVA distribution; up to 31.5 MVA power class
Construction Types
Oil-Immersed (ONAN/ONAF) & Cast Resin Dry-Type (AN/AF) & Pad-Mounted
Vector Group & Taps
Dyn11 (standard) or Yyn0; ±2 × 2.5% or ±4 × 2.5% OCTC
Short-Circuit Impedance
4.0% (50–630 kVA) / 4.5%–5.0% (800–1000 kVA) / 6.0% (1250–2500 kVA)
Applicable Standards
IEC 60076-1, IEC 60076-11, GB/T 1094, BS EN 50588, SANS 780
IEC / IEEE Reference Data
| Rated Capacity | Voltage Ratio (HV / LV) | No-Load Loss (P0) | Load Loss (Pk) | Impedance (Uk%) | No-Load Current (I0%) | Approx. Total Weight |
|---|---|---|---|---|---|---|
| 50 kVA | 11 / 0.4 kV | 105 W | 870 W | 4.0% | 1.4% | 420 kg |
| 100 kVA | 11 / 0.4 kV | 170 W | 1,500 W | 4.0% | 1.2% | 640 kg |
| 200 kVA | 11 / 0.4 kV | 290 W | 2,600 W | 4.0% | 1.0% | 960 kg |
| 315 kVA | 11 / 0.4 kV | 410 W | 3,650 W | 4.0% | 0.9% | 1,280 kg |
| 500 kVA | 11 / 0.4 kV | 590 W | 5,150 W | 4.0% | 0.8% | 1,750 kg |
| 630 kVA | 11 / 0.4 kV | 710 W | 6,200 W | 4.5% | 0.7% | 2,080 kg |
| 800 kVA | 11 / 0.4 kV | 860 W | 7,500 W | 5.0% | 0.7% | 2,480 kg |
| 1000 kVA | 11 / 0.4 kV | 1,030 W | 9,000 W | 5.0% | 0.6% | 2,920 kg |
| 1250 kVA | 11 / 0.4 kV | 1,220 W | 11,000 W | 5.5% | 0.6% | 3,520 kg |
| 1600 kVA | 11 / 0.4 kV | 1,480 W | 13,500 W | 6.0% | 0.5% | 4,260 kg |
| 2000 kVA | 11 / 0.4 kV | 1,810 W | 16,200 W | 6.0% | 0.5% | 5,150 kg |
| 2500 kVA | 11 / 0.4 kV | 2,150 W | 19,500 W | 6.0% | 0.4% | 6,180 kg |
Guaranteed parameters based on standard factory testing. Custom loss levels (Tier-2 Ecodesign, DOE 2016, and high-efficiency low-noise designs) are engineered on request.
High-precision 3D component breakdown of 11kV Distribution & Power Transformers illustrating CRGO silicon steel core assembly, electrolytic copper windings, insulation, and protection accessories.
Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.
100% full routine tests (IEC 60076) conducted before export packing.
Engineering Submittal & Layout Workbench
Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.
International utility & industrial submittal specifications
| Overall Length (L) | 1,750 mm |
|---|---|
| Overall Width (W) | 1,120 mm |
| Overall Height (H) | 1,780 mm |
| Roller Wheel Track Gauge (D) | 820 mm |
| Total Equipment Net Weight | 3,820 kg |
| Min Substation Clearance | 1,000 mm surrounding |
| Rated Voltage / System | 11 kV / 33 kV Dual Primary |
| Applicable Standard | IEC 60076-1 / IEEE C57 |
Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.
Factory Facility & Verification
Direct visual proof of XinHuan's manufacturing capability in Hefei, China. Unedited photographs showing our finished distribution transformer workshop, marked finished products area, cast resin dry-type stock, and export container loading.
Real completed units staged in orderly rows, ready for final project inspection, FAT witnessing, and international dispatch.
F/H-class cast resin coils and harmonic mitigation dry-type distribution transformers in stock.
Clear production-stage segregation and routine quality verification for procurement teams prior to container packaging.
Precision silicon steel core stacking, copper coil winding assembly, and tank fabrication.
Heavy-duty vacuum autoclave drying process ensuring zero residual moisture in coil insulation.
Direct container packing and heavy-duty ocean freight loading outside our Hefei facility.
Quality & Compliance
Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.
Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.
Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.
Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.
Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.
On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.
Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).
Technical Q&A
Export Markets
Engineering Reference Silo
11kV Distribution & Power Transformers — Direct Factory Quotation
Include capacity (kVA), primary voltage (11 kV), secondary voltage (400V/415V), standard (IEC/GB), destination port, and required quantity. Our engineers respond with certified data sheets within 24 hours.