50 kVA 33kV Three-Phase Oil-Immersed Distribution Transformer
This 50 kVA oil-immersed distribution transformer is designed for reliable power...
Voltage Class — 33 kV Medium Voltage Distribution
33 kV (33,000V nominal, Um = 36kV, 170kV BIL) is the dominant sub-transmission and primary distribution backbone for Sub-Saharan Africa, the Middle East, South America, and Commonwealth grids. XinHuan manufactures high-reliability IEC 60076 oil-immersed distribution transformers (50 kVA to 5000 kVA) and primary substation transformers (up to 31.5 MVA) with factory-direct pricing, certified routine FAT reports, and rapid ocean shipping to Lagos, Mombasa, Tema, Durban, and Middle East ports.
Product Range
Standard and custom capacities available for global utility, industrial, and commercial projects. View complete catalog →
This 50 kVA oil-immersed distribution transformer is designed for reliable power...
This 80 kVA oil-immersed distribution transformer is designed for dependable...
This 50 kVA oil-immersed distribution transformer is designed for dependable...
This 500 kVA oil-immersed distribution transformer is designed for reliable power...
This 400 kVA oil-immersed distribution transformer is designed for reliable power...
This 315 kVA oil-immersed distribution transformer is designed for reliable power...
This 250 kVA oil-immersed distribution transformer is designed for reliable power...
This 200 kVA oil-immersed distribution transformer is designed for reliable power...
This 160 kVA oil-immersed distribution transformer is designed for reliable power...
This 100 kVA oil-immersed distribution transformer is designed for reliable power...
This 630 kVA hermetically sealed three-phase transformer is built for...
This 400 kVA hermetically sealed three-phase transformer is built for...
Technical Overview
33 kV primary distribution lines enable long-distance rural electrification and heavy industrial power transmission with significantly lower I²R feeder line losses compared to 11kV networks. In Nigeria (NEMSA/DisCos), Kenya (KPLC/REREC), Ghana (ECG/VRA), Zambia (ZESCO), South Africa (Eskom), and Saudi Arabia (SEC), 33kV transformers step down directly to 415V/240V for industrial estates or 11kV for municipal distribution injection substations.
XinHuan manufactures both hermetically sealed corrugated-tank units (up to 2500 kVA) and conservator-type transformers equipped with double-float Buchholz relays, magnetic oil level gauges, dehydrating silica gel breathers, and dial thermometers. High-permeability grain-oriented CRGO silicon steel step-lap cores deliver ultra-low no-load idle losses compliant with IEC Tier 2 and local utility efficiency mandates.
Every 33kV transformer is subjected to 100% routine Factory Acceptance Testing (FAT) in our Hefei high-voltage laboratory: DC winding resistance, ratio and Dyn11/YNd11 vector check, short-circuit impedance and load loss (Pk), 70 kV 1-minute power-frequency separate-source withstand, and induced overvoltage test. Third-party inspection (SGS, Bureau Veritas, Intertek) is warmly welcomed.
Rated High Voltage (HV)
33 kV (30 kV / 33 kV / 34.5 kV / 35 kV nominal options, Um = 36 kV)
Rated Low Voltage (LV)
0.415 kV (415V/240V), 0.400 kV (400V/230V), 11 kV, or 6.6 kV
Lightning Impulse Withstand (BIL)
170 kV peak lightning impulse / 70 kV power frequency withstand (IEC 60076-3)
Capacity Range
50 kVA – 5000 kVA distribution; up to 31.5 MVA sub-transmission
Cooling Method
ONAN (Oil Natural Air Natural) standard; ONAF dual-speed fans available
Vector Group & Taps
Dyn11 (standard distribution) or YNd11 / YNyn0; ±2×2.5% or ±4×2.5% OCTC (OLTC available)
Bushings & Creepage
Outdoor porcelain or silicone rubber bushings with >= 900mm heavy-pollution creepage
Applicable Standards
IEC 60076-1, IEC 60076-2, IEC 60076-3, GB/T 1094, SANS 780, BS 171
IEC / IEEE Reference Data
| Rated Capacity | Voltage Ratio (HV / LV) | No-Load Loss (P0) | Load Loss (Pk) | Impedance (Uk%) | No-Load Current (I0%) | Approx. Total Weight |
|---|---|---|---|---|---|---|
| 100 kVA | 33 / 0.415 kV | 230 W | 1,800 W | 4.5% | 1.2% | 820 kg |
| 200 kVA | 33 / 0.415 kV | 380 W | 2,950 W | 4.5% | 1.0% | 1,180 kg |
| 315 kVA | 33 / 0.415 kV | 520 W | 4,100 W | 4.5% | 0.9% | 1,540 kg |
| 500 kVA | 33 / 0.415 kV | 740 W | 5,800 W | 5.0% | 0.8% | 2,150 kg |
| 630 kVA | 33 / 0.415 kV | 890 W | 6,900 W | 5.0% | 0.7% | 2,580 kg |
| 800 kVA | 33 / 0.415 kV | 1,060 W | 8,200 W | 5.5% | 0.7% | 3,050 kg |
| 1000 kVA | 33 / 0.415 kV | 1,250 W | 9,800 W | 5.5% | 0.6% | 3,650 kg |
| 1250 kVA | 33 / 0.415 kV | 1,480 W | 11,800 W | 6.0% | 0.6% | 4,380 kg |
| 1600 kVA | 33 / 0.415 kV | 1,780 W | 14,500 W | 6.25% | 0.5% | 5,250 kg |
| 2000 kVA | 33 / 0.415 kV | 2,150 W | 17,500 W | 6.5% | 0.5% | 6,400 kg |
| 2500 kVA | 33 / 0.415 kV | 2,550 W | 21,000 W | 6.5% | 0.4% | 7,600 kg |
| 3150 kVA | 33 / 0.415 kV | 3,100 W | 25,500 W | 7.0% | 0.4% | 9,100 kg |
| 5000 kVA | 33 / 11 kV | 4,400 W | 35,000 W | 7.5% | 0.3% | 13,500 kg |
Guaranteed parameters based on standard factory testing. Custom loss levels (Tier-2 Ecodesign, DOE 2016, and high-efficiency low-noise designs) are engineered on request.
High-precision 3D component breakdown of 33kV Distribution & Power Transformers illustrating CRGO silicon steel core assembly, electrolytic copper windings, insulation, and protection accessories.
Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.
100% full routine tests (IEC 60076) conducted before export packing.
Engineering Submittal & Layout Workbench
Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.
International utility & industrial submittal specifications
| Overall Length (L) | 1,750 mm |
|---|---|
| Overall Width (W) | 1,120 mm |
| Overall Height (H) | 1,780 mm |
| Roller Wheel Track Gauge (D) | 820 mm |
| Total Equipment Net Weight | 3,820 kg |
| Min Substation Clearance | 1,000 mm surrounding |
| Rated Voltage / System | 11 kV / 33 kV Dual Primary |
| Applicable Standard | IEC 60076-1 / IEEE C57 |
Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.
Factory Facility & Verification
Direct visual proof of XinHuan's manufacturing capability in Hefei, China. Unedited photographs showing our finished distribution transformer workshop, marked finished products area, cast resin dry-type stock, and export container loading.
Real completed units staged in orderly rows, ready for final project inspection, FAT witnessing, and international dispatch.
F/H-class cast resin coils and harmonic mitigation dry-type distribution transformers in stock.
Clear production-stage segregation and routine quality verification for procurement teams prior to container packaging.
Precision silicon steel core stacking, copper coil winding assembly, and tank fabrication.
Heavy-duty vacuum autoclave drying process ensuring zero residual moisture in coil insulation.
Direct container packing and heavy-duty ocean freight loading outside our Hefei facility.
Quality & Compliance
Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.
Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.
Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.
Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.
Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.
On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.
Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).
Technical Q&A
Export Markets
Engineering Reference Silo
33kV Distribution & Power Transformers — Direct Factory Quotation
Include capacity (kVA), capacity (kVA), primary (33kV), secondary (415V or 11kV), cooling (ONAN/ONAF), destination port, and required quantity. Our engineers respond with certified data sheets within 24 hours.