2500 kVA Distribution & Power Transformers — 2500 kVA Transformer Manufacturer & Export Factory China | 11kV 33kV Oil & Dry Type

Capacity Class — 2500 kVA

2500 kVA Distribution & Power Transformers

2500 kVA is the most widely searched capacity for heavy industrial facilities, commercial complexes, substation step-down feeders, and renewable energy plants. XinHuan manufactures IEC 60076 and ANSI C57.12 2500 kVA oil-immersed, cast resin dry-type, anti-corrosion, and high-altitude transformers at 11 kV, 22 kV, 33 kV, and 35 kV.

2500 kVA
rating
11–35 kV
HV class
IEC 60076
standard
24h
quote response

Product Range

2500 kVA Distribution & Power Transformers — 53 Models Available

Standard and custom capacities available for global utility, industrial, and commercial projects. View complete catalog →

Technical Overview

2500 kVA — High Capacity Power & Distribution Core

2500 kVA (2.5 MVA) transformers bridge medium-voltage distribution grids with heavy industrial loads, mining facilities, data centers, and renewable energy substations. Available in both oil-immersed (S11/S13/S22 series) and cast resin dry-type (SCB13/SCB14 series) configurations.

XinHuan manufactures 2500 kVA units to IEC 60076 as the primary standard, with GB/T 1094 and ANSI C57.12 compliance. All 2500 kVA transformers undergo full routine testing (winding resistance, voltage ratio, phase displacement, short-circuit impedance, load and no-load losses, separate-source AC withstand voltage, and induced overvoltage withstand voltage).

Key options include: ONAN/ONAF dual cooling, off-circuit tap changer (±2 x 2.5%) or on-load tap changer (OLTC), Buchholz relay, magnetic oil level gauge, winding thermometer with alarm contacts, and IP23/IP54 protective enclosures for dry-type units.

2500 kVA Distribution & Power Transformers — Key Specifications

  • Rated Capacity

    2500 kVA (2.5 MVA)

  • Primary Voltage

    11 kV, 22 kV, 33 kV, 35 kV

  • Secondary Voltage

    0.4 kV, 0.415 kV, 0.69 kV, 6.3 kV, 10.5 kV

  • Standard

    IEC 60076-1 / GB/T 1094 / ANSI C57.12

  • Cooling Class

    ONAN / ONAF (Oil Immersed) | AN / AF (Dry Type)

  • Vector Group

    Dyn11, Yyn0, YNd11

  • No-Load Loss

    Engineered to low-loss S13/S22 and SCB14 standard

  • Short Circuit Impedance

    6.0% – 8.0% (standard per IEC)

IEC / IEEE Reference Data

2500 kVA Distribution & Power Transformers — Standard Capacity & Loss Parameters

Request Custom Datasheet
2500 kVA Distribution & Power Transformers — Standard Capacity (kVA), No-Load Loss (P0), Load Loss (Pk), Impedance (Uk%), and Weight Specification Table
Rated Capacity Voltage Ratio (HV / LV) No-Load Loss (P0) Load Loss (Pk) Impedance (Uk%) No-Load Current (I0%) Approx. Total Weight
2500 kVA (S13 Oil) 11 / 0.415 kV 2,290 W 21,500 W 5.0% 0.4% 6,950 kg
2500 kVA (S20 Eco) 11 / 0.415 kV 1,850 W 18,200 W 5.0% 0.3% 7,400 kg
2500 kVA (S13 Oil) 33 / 0.415 kV 2,550 W 21,000 W 6.5% 0.4% 7,600 kg
2500 kVA (S13 Oil) 33 / 11 kV 2,480 W 20,500 W 6.5% 0.4% 7,850 kg
2500 kVA (ANSI 60Hz) 13.8 / 0.48 kV 2,580 W 17,900 W 6.0% 0.4% 7,100 kg
2500 kVA (ANSI Pad) 34.5 / 0.48 kV 2,750 W 19,200 W 6.0% 0.4% 7,800 kg
2500 kVA (SCB14 Dry) 11 / 0.415 kV 3,850 W 18,200 W 6.0% 0.5% 6,800 kg
2500 kVA (SCB14 Dry) 33 / 0.415 kV 4,350 W 20,500 W 7.0% 0.5% 7,500 kg

Guaranteed parameters based on standard factory testing. Custom loss levels (Tier-2 Ecodesign, DOE 2016, and high-efficiency low-noise designs) are engineered on request.

2500 kVA Distribution & Power Transformers — 3D Engineering Anatomy Cutaway

High-precision 3D component breakdown of 2500 kVA Distribution & Power Transformers illustrating CRGO silicon steel core assembly, electrolytic copper windings, insulation, and protection accessories.

2500 kVA Distribution & Power Transformers internal 3D cutaway showing silicon steel core, copper windings, and tap changer
2500 kVA Distribution & Power Transformers — Internal Core, Winding & Dielectric Assembly
High-Grade Silicon Core
Electrolytic Copper Coil
Off-Circuit / OLTC Tap Switch
Buchholz & Temp Relays

2500 kVA Distribution & Power Transformers — Factory Acceptance Testing (FAT)

Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.

100% full routine tests (IEC 60076) conducted before export packing.

Engineering Submittal & Layout Workbench

Substation Room Fit & Multi-Equipment CAD Footprints

Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.

Available Ratings:
IEC 60076-1 Submittal Specs
XinHuan Engineering GA CAD Drawing
XinHuan Engineering Single Line Diagram (SLD)
11kV / 33kV Dual Voltage
IEC 60076 / IEEE Compliant
100% Routine Factory Tested
Export Nitrogen / Seaworthy Pack

1000 kVA Technical Dimensions

IEC 60076-1

International utility & industrial submittal specifications

Overall Length (L) 1,750 mm
Overall Width (W) 1,120 mm
Overall Height (H) 1,780 mm
Roller Wheel Track Gauge (D) 820 mm
Total Equipment Net Weight 3,820 kg
Min Substation Clearance 1,000 mm surrounding
Rated Voltage / System 11 kV / 33 kV Dual Primary
Applicable Standard IEC 60076-1 / IEEE C57
Download Technical Data Sheet (PDF) Request Factory Engineering Submittal Package

Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.

Quality & Compliance

Certified B2B Manufacturing & Laboratory Performance

Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.

IAF / CNAS Accredited

ISO 9001:2015 Quality System

Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.

Environmental System

ISO 14001:2015 Environmental

Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.

Occupational Health

ISO 45001:2018 Safety System

Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.

CNAS Lab Type Tests

IEC 60076 & GB Type Tests

Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.

SGS Audited Supplier

SGS Verified Manufacturer Audit

On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.

≥180 Units/Yr Export

International Delivery Certificate

Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).

Technical Q&A

Frequently Asked Questions — 2500 kVA Distribution & Power Transformers

2500 kVA is the maximum rating typically permitted in compact prefabricated substations and indoor distribution rooms while remaining transportable in standard dry-van containers. It supplies approximately 3,478 Amperes at 415V, making it the workhorse capacity for heavy factories, processing mills, multi-megawatt data halls, and solar farm inverter stations.

All XinHuan 2500 kVA transformers are designed and verified to withstand the dynamic and thermal effects of a external short circuit per IEC 60076-5. Windings are wound with high-tensile copper or work-hardened aluminum, clamped with heavy-duty structural steel frames and hydraulic pre-compression to prevent coil deformation.

An OCTC (standard ±2×2.5%) requires de-energizing the transformer to manually change tap positions, suitable for networks with stable grid voltage. An OLTC (e.g. ±8×1.25% or ±4×2.5%) adjusts tap positions under load automatically via an AVR relay, vital for grids with severe voltage fluctuations or renewable power feed-in.

Equipping an oil-immersed unit with ONAF dual-speed cooling fans increases continuous throughput from 2500 kVA to 3150 kVA (+26%). For cast-resin dry-type units, adding cross-flow cooling fans (AF) boosts continuous capacity from 2500 kVA to 3300 kVA (+33%).

Standard accessories include: dual-float Buchholz relay (alarm + trip), multi-contact magnetic oil level gauge, dial thermometer with max indicator and micro-switches, rapid pressure relief valve with directional discharge nozzle, and dehydrating silica gel breather.

Yes. For successful parallel operation, both units must have identical voltage ratio, same vector group (e.g. Dyn11), short-circuit impedance matching within ±10% tolerance, and identical polarity. XinHuan custom-engineers impedance matching specifically for parallel substation pairs.

A typical 2500 kVA 11/0.415kV oil transformer measures approximately 2,450 × 1,650 × 2,250 mm with a total weight of ~6,950 kg. It fits securely inside a standard 20-foot GP ocean shipping container, with wheels detached and strapped to heavy wooden skids.

Please provide: primary voltage (11kV, 22kV, 33kV, or 34.5kV), secondary voltage (400V, 415V, 480V, or 690V), oil or dry type, conductor material (copper or aluminum), cooling (ONAN or ONAF), tap changer type (OCTC or OLTC), and destination port for an authoritative CIF proposal.

Engineering Reference Silo

Transformer Category Pillars & International Standards

China Transformer Manufacturer Export Hub

2500 kVA Distribution & Power Transformers — Direct Factory Quotation

Request Engineering Submittals & Price

Include capacity (kVA), primary voltage (e.g. 11kV/33kV), oil or dry type, vector group, destination port, and required quantity. Our engineers respond with certified data sheets within 24 hours.