25 kVA three-phase dry-type isolation transformer manufactured with high-grade silicon steel cores and Class H copper/aluminum windings for continuous heavy-duty industrial duty.
| Product name | Three phase dry type isolation transformer |
|---|---|
| Voltage accuracy | ±1% |
| Voltage variation rate | ≤1.5 |
| Insulation resistance | ≥150M |
| Electrical strength | 3000VAC/1min |
| Design life | 20 years |
| Cooling mode | Dry air cooling |
| Input voltage | 660V 440V 380V 220V(Customizable voltage) |
| Temperature rise | ≤60℃ |
| Noise | 35db(Within meters) |
| Product name | Three phase dry type isolation transformer |
| Voltage accuracy | ±1% |
| Voltage variation rate | ≤1.5 |
| Insulation resistance | ≥150M |
| Electrical strength | 3000VAC/1min |
Engineering Submittal & Layout Workbench
Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.
International utility & industrial submittal specifications
| Overall Length (L) | 1,750 mm |
|---|---|
| Overall Width (W) | 1,120 mm |
| Overall Height (H) | 1,780 mm |
| Roller Wheel Track Gauge (D) | 820 mm |
| Total Equipment Net Weight | 3,820 kg |
| Min Substation Clearance | 1,000 mm surrounding |
| Rated Voltage / System | 11 kV / 33 kV Dual Primary |
| Applicable Standard | IEC 60076-1 / IEEE C57 |
Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.
PSCAD™ & ETAP® Grid Simulation
Precision core excitation characteristics, non-linear knee inflection (\(V_k\)), and air-core reactance (\(X_{\text{air}}\)) calibrated for XH-ISO Three Phase Dry Type Ac Transformer 1900kva 690v 400v 380v Ce Iso Step Down Transformer With High Efficiency For Factory.
| PSCAD Simulation Point | Voltage (\(V_{\text{pu}}\)) | Flux (\(\lambda\), Wb-t) | Current (\(I_{\text{pu}}\)) | Current (A) |
|---|
Built with tier-1 certified raw materials engineered for long operational life (>30 years), superior dielectric withstand, and high short-circuit withstand capacity.
High-grade grain-oriented cold-rolled silicon steel with step-lap mitered joints for low $P_o$ losses.
Electrolytic oxygen-free copper with high thermal grade insulation for surge resistance.
De-energized tap switch ($\pm 2 \times 2.5\%$) or on-load vacuum tap changer (OLTC) optional.
Buchholz gas relay, magnetic oil gauge (MOG), and dial thermometers with alarm contacts.
Every transformer unit manufactured by XinHuan undergoes mandatory routine factory testing prior to container dispatch. Full certified routine and type test submittal reports are provided with commercial documentation:
Megger test (HV to LV, HV to Earth, LV to Earth) >1000 MΩ.
Turns ratio check across all taps with phase displacement check.
Precision Kelvin bridge measurement across all tap positions.
Load loss ($P_k$) measurement corrected to reference temp (75°C).
Core excitation test ($P_o$ and $I_o$) at rated sinusoidal voltage.
Power-frequency separate source test (e.g. 50kV/70kV 1 min).
Full wave & chopped wave impulse withstand (BIL up to 170kV).
Ultra-low discharge (<5 pC) and pressurized oil/gas tightness test.
Plywood Export Crate Packaging, 15-20 Days Lead Time
Standard manufacturing cycle is 4 to 6 weeks from approval of GA blueprints and single-line diagrams.
Vacuum moisture barrier preservation, nitrogen blanketing, and reinforced steel-frame structural crate skids.
Fast ocean freight to Port of Chancay & Callao (25-35 days), Manila, Lagos, and Middle East ports.
Watch XinHuan technicians perform routine dielectric testing, winding insulation checks, and quality inspections inside our Hefei manufacturing plant.
Send your single-line diagram (SLD), voltage ratings, or tender specifications. Our chief electrical engineers will review and issue an actionable CIF quotation within 24 hours.