Compact Substations American Type (ANSI) SKU: 150_KVA_13_8KV_THREE_PHASE_PAD_MOUNTED_TRANSFORMER_ANSI_C57

150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed)

150 kVA three-phase loop-feed pad-mounted transformer with 6 high-voltage bushing wells (IEEE 386) and 4-position sectionalizing oil load break switch. Engineered for commercial plazas and industrial underground loops.

Compliance Standards
IEC • ANSI • IEEE • GB
Quality Inspection
100% FAT Routine Tested
Engineering CAD
2D CAD / SLD Schematics
Global Logistics
Direct Seaport CIF Export
Engineering Datasheet

150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed) — Technical Parameters & Ratings

Print Submittal Datasheet IEC / ANSI Certified Factory Standard

Specification data is being updated for this product SKU.

Engineering Submittal & Layout Workbench

Substation Room Fit & Multi-Equipment CAD Footprints

Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.

Available Ratings:
IEC 60076-1 Submittal Specs
XinHuan Engineering GA CAD Drawing
XinHuan Engineering Single Line Diagram (SLD)
11kV / 33kV Dual Voltage
IEC 60076 / IEEE Compliant
100% Routine Factory Tested
Export Nitrogen / Seaworthy Pack

1000 kVA Technical Dimensions

IEC 60076-1

International utility & industrial submittal specifications

Overall Length (L) 1,750 mm
Overall Width (W) 1,120 mm
Overall Height (H) 1,780 mm
Roller Wheel Track Gauge (D) 820 mm
Total Equipment Net Weight 3,820 kg
Min Substation Clearance 1,000 mm surrounding
Rated Voltage / System 11 kV / 33 kV Dual Primary
Applicable Standard IEC 60076-1 / IEEE C57
Download Technical Data Sheet (PDF) Request Factory Engineering Submittal Package

Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.

PSCAD™ & ETAP® Grid Simulation

Non-Linear V-I Saturation Curve & Air-Core Inductance (\(L_{\text{air}}\))

Precision core excitation characteristics, non-linear knee inflection (\(V_k\)), and air-core reactance (\(X_{\text{air}}\)) calibrated for 150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed).

Full Engineering Suite
Quick Rating Switch
kVA
kV
%
2.10
1.80 (Compact Shell) 2.10 (Standard IEEE / CIGRE) 2.50 (Outer HV Layer)
Air-Core Inductance (\(L_{\text{air}}\)) 18.7× In Peak
81.65 mH
Reactance
25.65 Ω
Knee \(V_k\)
13.0 kV
Decay \(\tau\)
0.17 s
Request Certified Factory Excitation & Inrush Submittal
Non-Linear Magnetization Characteristic (\(\lambda - I_{\text{exc}}\)) Interactive Vector Plot
Linear Core Zone Knee Transition Air-Core Slope (\(X_{\text{air}}\))
PSCAD Simulation Point Voltage (\(V_{\text{pu}}\)) Flux (\(\lambda\), Wb-t) Current (\(I_{\text{pu}}\)) Current (A)
Data formatted for direct entry into PSCAD Classical Saturable Transformer and UMEC core components per IEEE C57.12.00 & CIGRE 33.02.
150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed) — XinHuan American-Type Pad-Mounted Substation Assembly Line
XinHuan Hefei Manufacturing Plant — American-Type Pad-Mounted Substation Assembly Line
Factory Build Quality

150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed) — Internal Construction & Premium Materials

Built with tier-1 certified raw materials engineered for long operational life (>30 years), superior dielectric withstand, and high short-circuit withstand capacity.

Silicon Steel Core

High-grade grain-oriented cold-rolled silicon steel with step-lap mitered joints for low $P_o$ losses.

100% Copper Windings

Electrolytic oxygen-free copper with high thermal grade insulation for surge resistance.

Loadbreak Switching

Two-position (radial) or four-position (loop feed) oil-immersed rotary loadbreak switch rated up to 630A.

ANSI Pad Protection

Bay-O-Net expulsion fuse in series with ELSP back-up fuse, automatic pressure relief valve, and liquid level gauge.

Quality Assurance

150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed) — 100% Factory Acceptance Testing (FAT)

CNAS & ISO 9001 Certified

Every transformer unit manufactured by XinHuan undergoes mandatory routine factory testing prior to container dispatch. Full certified routine and type test submittal reports are provided with commercial documentation:

1. Insulation Resistance

Megger test (HV to LV, HV to Earth, LV to Earth) >1000 MΩ.

2. Voltage Ratio & Vector

Turns ratio check across all taps with phase displacement check.

3. Winding DC Resistance

Precision Kelvin bridge measurement across all tap positions.

4. Short-Circuit Impedance

Load loss ($P_k$) measurement corrected to reference temp (75°C).

5. No-Load Loss & Current

Core excitation test ($P_o$ and $I_o$) at rated sinusoidal voltage.

6. AC Voltage Withstand

Power-frequency separate source test (e.g. 50kV/70kV 1 min).

7. Lightning Impulse (BIL)

Full wave & chopped wave impulse withstand (BIL up to 170kV).

8. Partial Discharge & Seals

Dead-front dielectric test, ANSI C57.12.28 tamper resistance & pressurized tank seal verification.

Logistics Intelligence

150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed) — Export Packaging & Seaport Logistics

Global CIF / FOB Delivery

Export-grade fumigated wooden case with internal bracing and waterproof barrier. Direct CIF/FOB shipping.

Production Lead Time

Standard manufacturing cycle is 4 to 6 weeks from approval of GA blueprints and single-line diagrams.

Heavy-Duty Export Packaging

Vacuum moisture barrier preservation, nitrogen blanketing, and reinforced steel-frame structural crate skids.

Direct Seaport Routes

Fast ocean freight to Port of Chancay & Callao (25-35 days), Manila, Lagos, and Middle East ports.

Equipment Video Inspection

100% Tested

Watch XinHuan technicians perform routine dielectric testing, winding insulation checks, and quality inspections inside our Hefei manufacturing plant.

Every unit 100% routine tested before container loading.
Direct Factory Consultation

Need Custom Project Engineering?

Send your single-line diagram (SLD), voltage ratings, or tender specifications. Our chief electrical engineers will review and issue an actionable CIF quotation within 24 hours.

Custom Voltage Ratios
High-Altitude Derating
Short-Circuit Impedance
Third-Party FAT Witness

150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed) — Engineering & Procurement FAQs

Frequently asked questions regarding specifications, certifications, and delivery for 150 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed).

Please send us your required capacity, primary voltage, secondary voltage, and destination port for 150 kVA Three-Phase Pad-Mounted Transformer (480Y/277V Loop Feed). Our engineering team will provide CAD submittals and an official factory direct quotation within 24 hours.

ANSI/IEEE C57.12.34 / IEEE C57.12.28 / IEEE C57.12.90

Standard manufacturing lead time is 4 to 6 weeks following approval of GA blueprints and single-line diagrams. Direct sea container shipping is available under FOB, CFR, or CIF terms with full customs documentation (Bill of Lading, Certificate of Origin, Test Reports).
PARENT ENGINEERING PILLAR IEEE C57.12.34 · Dead-Front Loop & Radial Feed (75–3000 kVA)

ANSI Pad-Mounted Transformers Pillar Guide

Compare full capacity no-load loss ($P_0$), load loss ($P_k$), impedance ($U_k\%$), dimensional weights, and routine test tolerances across all models in this series.

Engineering Reference Silo

Transformer Category Pillars & International Standards

China Transformer Manufacturer Export Hub

Ready to Proceed?

Request a Firm Quotation for 150 kVA 13.8kV Three-Phase Pad-Mounted...

Share your project specifications and receive an official CIF quotation within 24 hours.