75 kVA 13.8kV Three-Phase Pad-Mounted Transformer (480Y/277V Radial Feed)
75 kVA to 480Y/277V three-phase liquid-filled pad-mounted transformer built to...
Equipment Standard — ANSI/IEEE C57.12.34 · 60Hz Underground Distribution
XinHuan manufactures high-performance three-phase liquid-filled pad-mounted compartmental transformers (75 kVA to 3000 kVA, primary voltages up to 34.5 kV) engineered for underground distribution networks, commercial shopping centers, industrial plants, EV charging hubs, and solar PV farms across the Americas, Philippines, and Caribbean. Fully compliant with ANSI/IEEE C57.12.34 and tamper-resistant per ANSI C57.12.28.
Product Range
Standard and custom capacities available for global utility, industrial, and commercial projects. View complete catalog →
75 kVA to 480Y/277V three-phase liquid-filled pad-mounted transformer built to...
225 kVA to 208Y/120V three-phase pad-mounted transformer tailored for commercial...
150 kVA three-phase loop-feed pad-mounted transformer with 6 high-voltage bushing...
This 500 kva three-phase american type pad-mounted substation is an integrated...
This 500 kva three-phase american type pad-mounted substation is an integrated...
This 300 kva three-phase american type pad-mounted substation is an integrated...
3000 kVA / heavy-duty three-phase pad-mounted transformer engineered for...
1500 kVA to 480Y/277V three-phase compartmental pad-mounted transformer for heavy...
750 kVA / three-phase compartmental pad-mounted transformer for industrial...
Factory-direct 2500 kVA pad-mounted transformer engineered to ANSI C57.12.20...
This 2500 kva three-phase american type pad-mounted substation is an integrated...
This 1000 kva three-phase american type pad-mounted substation is an integrated...
Technical Overview
Pad-mounted compartmental transformers are the gold standard for underground electric distribution across North and Latin America, the Philippines, and international commercial complexes. Because these units are installed outdoors in public-accessible green spaces, tamper resistance and public safety are paramount. XinHuan builds every cabinet with full compliance to ANSI C57.12.28, featuring concealed stainless steel hinges, captive penta-head security bolts, interlocking doors (LV door must open before HV latch can be released), and pry-bar resistant sills with gaps under 6.35 mm.
Our transformers are available in both Radial Feed (3 HV bushing wells) and Loop Feed (6 HV bushing wells for continuous ring distribution and isolation) configurations. Using universal IEEE 386 dead-front bushing wells, operators can safely make and break load connections with 200A or 600A separable insulated elbow connectors. Internal protection incorporates drawout Bay-O-Net expulsion fuses in series with current-limiting backup fuses (ELSP) to clear both low-current thermal overloads and high-energy short circuits.
Every unit is 100% factory acceptance tested in accordance with IEEE C57.12.90: winding resistance, voltage ratio and polarity check, no-load loss and excitation current, short-circuit impedance and load loss (Pk), applied and induced potential dielectric tests, and pressure leak testing. All units are finished in durable Munsell Green (7GY 3.29/1.5) powder coating resisting salt spray, humidity, and extreme UV exposure.
Governing Standards
ANSI/IEEE C57.12.00, C57.12.34, C57.12.28 (Enclosure), C57.12.90 (Testing)
Capacity Range
75 kVA to 3000 kVA (Three Phase, 60 Hz or 50 Hz)
Primary Voltages (HV)
4.16 kV, 12.47 kV, 13.2 kV, 13.8 kV, 24.9 kV, 34.5Y/19.9 kV (Dead Front)
Secondary Voltages (LV)
208Y/120V, 480Y/277V, 240V Delta, 4160V
Feed Arrangement
Loop Feed (6 HV Bushings with 2/4-position oil switch) or Radial Feed (3 HV Bushings)
Enclosure Security
ANSI C57.12.28 tamper-proof, captive penta-head bolt, padlockable handle, Munsell Green
Primary Fuse Protection
Drawout Bay-O-Net overload fuses with internal backup current-limiting fuses (ELSP)
Dielectric Fluid Options
Mineral insulating oil (ASTM D3487) or Cargill FR3 natural ester biodegradable fluid
IEC / IEEE Reference Data
| Rated Capacity | Voltage Ratio (HV / LV) | No-Load Loss (P0) | Load Loss (Pk) | Impedance (Uk%) | No-Load Current (I0%) | Approx. Total Weight |
|---|---|---|---|---|---|---|
| 75 kVA | 13.8 kV / 480Y | 240 W | 980 W | 3.5% | 1.2% | 1,150 kg |
| 150 kVA | 13.8 kV / 480Y | 390 W | 1,650 W | 3.8% | 1.0% | 1,550 kg |
| 300 kVA | 13.8 kV / 480Y | 680 W | 2,950 W | 4.5% | 0.9% | 2,200 kg |
| 500 kVA | 13.8 kV / 480Y | 990 W | 4,400 W | 4.5% | 0.8% | 2,850 kg |
| 750 kVA | 13.8 kV / 480Y | 1,350 W | 6,200 W | 5.5% | 0.7% | 3,650 kg |
| 1000 kVA | 13.8 kV / 480Y | 1,680 W | 7,900 W | 5.75% | 0.6% | 4,400 kg |
| 1500 kVA | 13.8 kV / 480Y | 2,350 W | 11,200 W | 5.75% | 0.5% | 5,800 kg |
| 2000 kVA | 13.8 kV / 480Y | 2,950 W | 14,500 W | 6.0% | 0.5% | 7,100 kg |
| 2500 kVA | 13.8 kV / 480Y | 3,550 W | 17,800 W | 6.0% | 0.4% | 8,400 kg |
Guaranteed parameters based on standard factory testing. Custom loss levels (Tier-2 Ecodesign, DOE 2016, and high-efficiency low-noise designs) are engineered on request.
High-precision 3D component breakdown of Three-Phase Pad-Mounted Transformers (ANSI / IEEE C57) illustrating CRGO silicon steel core assembly, electrolytic copper windings, insulation, and protection accessories.
Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.
100% full routine tests (IEC 60076) conducted before export packing.
Engineering Submittal & Layout Workbench
Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.
International utility & industrial submittal specifications
| Overall Length (L) | 1,750 mm |
|---|---|
| Overall Width (W) | 1,120 mm |
| Overall Height (H) | 1,780 mm |
| Roller Wheel Track Gauge (D) | 820 mm |
| Total Equipment Net Weight | 3,820 kg |
| Min Substation Clearance | 1,000 mm surrounding |
| Rated Voltage / System | 11 kV / 33 kV Dual Primary |
| Applicable Standard | IEC 60076-1 / IEEE C57 |
Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.
Factory Facility & Verification
Direct visual proof of XinHuan's manufacturing capability in Hefei, China. Unedited photographs showing our finished distribution transformer workshop, marked finished products area, cast resin dry-type stock, and export container loading.
Real completed units staged in orderly rows, ready for final project inspection, FAT witnessing, and international dispatch.
F/H-class cast resin coils and harmonic mitigation dry-type distribution transformers in stock.
Clear production-stage segregation and routine quality verification for procurement teams prior to container packaging.
Precision silicon steel core stacking, copper coil winding assembly, and tank fabrication.
Heavy-duty vacuum autoclave drying process ensuring zero residual moisture in coil insulation.
Direct container packing and heavy-duty ocean freight loading outside our Hefei facility.
Quality & Compliance
Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.
Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.
Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.
Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.
Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.
On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.
Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).
Technical Q&A
Export Markets
Engineering Reference Silo
Three-Phase Pad-Mounted Transformers (ANSI / IEEE C57) — Direct Factory Quotation
Include capacity (kVA), capacity (kVA), primary voltage (e.g. 13.8kV), secondary (480Y/277V), feed (Loop/Radial), destination port, and required quantity. Our engineers respond with certified data sheets within 24 hours.