500 kVA 11kV SCB14 High-Efficiency Three-Phase Dry Transformer
This 500 kva scb14 high-efficiency three-phase dry transformer is designed for...
Voltage Class — 11kV Cast Resin Dry-Type
XinHuan manufactures high-performance 11kV cast resin dry-type transformers (50 kVA to 3150 kVA) engineered for indoor commercial substations, high-rise buildings, hospitals, data centers, and underground infrastructure. Certified to IEC 60076-11 with F1 fire-behavior, C2 climatic resistance, and E2 environmental resilience, delivering void-free vacuum casting and partial discharge < 10 pC.
Product Range
Standard and custom capacities available for global utility, industrial, and commercial projects. View complete catalog →
This 500 kva scb14 high-efficiency three-phase dry transformer is designed for...
This 630 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 500 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 400 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 315 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 250 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 200 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 160 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 100 kva scb13 three-phase cast resin dry-type transformer is designed for...
This 2500 kva scb14 high-efficiency three-phase dry transformer is designed for...
This 1600 kva scb14 high-efficiency three-phase dry transformer is designed for...
This 1000 kva scb14 high-efficiency three-phase dry transformer is designed for...
Technical Overview
Cast resin dry-type transformers eliminate oil leakage and fire hazards, making 11kV dry-type units the mandatory choice for indoor urban substations, shopping malls, hospitals, and offshore platforms. XinHuan utilizes high-grade vacuum epoxy casting technology with quartz filler, ensuring high mechanical short-circuit withstand and moisture resistance.
Both high-voltage (11kV) and low-voltage (0.4kV) windings are wound with electrolytic copper or aluminum foil and encapsulated under high vacuum (<1 mbar). The glass fiber reinforced solid insulation prevents insulation breakdown and resists thermal aging up to Class F (155°C) or Class H (180°C).
Each unit comes equipped with PT100 temperature sensors embedded in every LV phase winding, connected to a digital temperature controller (BWDK series) with automatic cooling fan control, over-temperature alarm, and trip contacts. IP20, IP23, or IP54 enclosures with safety interlocks are available.
Rated HV Voltage
11 kV (10 kV / 10.5 kV / 11.5 kV / 12 kV options)
Rated LV Voltage
0.4 kV / 0.415 kV / 0.433 kV / 0.69 kV
Capacity Range
50 kVA – 3150 kVA (Three Phase 50Hz / 60Hz)
Insulation Class
Class F (155°C) / Class H (180°C)
Partial Discharge
< 10 pC (tested per IEC 60076-11)
Environmental / Fire Class
E2 (Environmental), C2 (Climatic), F1 (Fire Behaviour)
Temperature Rise Limit
100K (Class F) / 125K (Class H)
Enclosure Protection
IP00 (Core & Coil), IP20, IP23 (Outdoor / Drip-Proof), IP54
IEC / IEEE Reference Data
| Rated Capacity | Voltage Ratio (HV / LV) | No-Load Loss (P0) | Load Loss (Pk) | Impedance (Uk%) | No-Load Current (I0%) | Approx. Total Weight |
|---|---|---|---|---|---|---|
| 50 kVA | 11 / 0.415 kV | 260 W | 1,080 W | 4.0% | 1.3% | 420 kg |
| 100 kVA | 11 / 0.415 kV | 370 W | 1,570 W | 4.0% | 1.1% | 610 kg |
| 160 kVA | 11 / 0.415 kV | 500 W | 2,130 W | 4.0% | 1.0% | 830 kg |
| 200 kVA | 11 / 0.415 kV | 580 W | 2,480 W | 4.0% | 0.9% | 950 kg |
| 250 kVA | 11 / 0.415 kV | 670 W | 2,760 W | 4.0% | 0.8% | 1,120 kg |
| 315 kVA | 11 / 0.415 kV | 810 W | 3,410 W | 4.0% | 0.8% | 1,340 kg |
| 400 kVA | 11 / 0.415 kV | 980 W | 3,990 W | 4.0% | 0.7% | 1,620 kg |
| 500 kVA | 11 / 0.415 kV | 1,160 W | 4,880 W | 4.0% | 0.7% | 1,890 kg |
| 630 kVA | 11 / 0.415 kV | 1,340 W | 5,880 W | 4.5% | 0.6% | 2,280 kg |
| 800 kVA | 11 / 0.415 kV | 1,520 W | 6,960 W | 4.5% | 0.6% | 2,750 kg |
| 1000 kVA | 11 / 0.415 kV | 1,770 W | 8,130 W | 6.0% | 0.5% | 3,350 kg |
| 1250 kVA | 11 / 0.415 kV | 2,090 W | 9,690 W | 6.0% | 0.5% | 3,950 kg |
| 1600 kVA | 11 / 0.415 kV | 2,450 W | 11,730 W | 6.0% | 0.5% | 4,800 kg |
| 2000 kVA | 11 / 0.415 kV | 3,050 W | 14,400 W | 6.0% | 0.5% | 5,850 kg |
| 2500 kVA | 11 / 0.415 kV | 3,850 W | 18,200 W | 6.0% | 0.5% | 6,800 kg |
Guaranteed parameters based on standard factory testing. Custom loss levels (Tier-2 Ecodesign, DOE 2016, and high-efficiency low-noise designs) are engineered on request.
High-precision 3D component breakdown of 11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) illustrating CRGO silicon steel core assembly, electrolytic copper windings, insulation, and protection accessories.
Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.
100% full routine tests (IEC 60076) conducted before export packing.
Engineering Submittal & Layout Workbench
Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.
International utility & industrial submittal specifications
| Overall Length (L) | 1,750 mm |
|---|---|
| Overall Width (W) | 1,120 mm |
| Overall Height (H) | 1,780 mm |
| Roller Wheel Track Gauge (D) | 820 mm |
| Total Equipment Net Weight | 3,820 kg |
| Min Substation Clearance | 1,000 mm surrounding |
| Rated Voltage / System | 11 kV / 33 kV Dual Primary |
| Applicable Standard | IEC 60076-1 / IEEE C57 |
Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.
Factory Facility & Verification
Direct visual proof of XinHuan's manufacturing capability in Hefei, China. Unedited photographs showing our finished distribution transformer workshop, marked finished products area, cast resin dry-type stock, and export container loading.
Real completed units staged in orderly rows, ready for final project inspection, FAT witnessing, and international dispatch.
F/H-class cast resin coils and harmonic mitigation dry-type distribution transformers in stock.
Clear production-stage segregation and routine quality verification for procurement teams prior to container packaging.
Precision silicon steel core stacking, copper coil winding assembly, and tank fabrication.
Heavy-duty vacuum autoclave drying process ensuring zero residual moisture in coil insulation.
Direct container packing and heavy-duty ocean freight loading outside our Hefei facility.
Quality & Compliance
Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.
Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.
Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.
Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.
Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.
On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.
Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).
Technical Q&A
Export Markets
Engineering Reference Silo
11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — Direct Factory Quotation
Include capacity (kVA), capacity in kVA, primary voltage (11kV), enclosure type (IP00/IP20/IP23), copper or aluminum winding, destination port, and required quantity. Our engineers respond with certified data sheets within 24 hours.