11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — 11kV Dry-Type Transformer Manufacturer China | Cast Resin SCB14 | XinHuan

Voltage Class — 11kV Cast Resin Dry-Type

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14)

XinHuan manufactures high-performance 11kV cast resin dry-type transformers (50 kVA to 3150 kVA) engineered for indoor commercial substations, high-rise buildings, hospitals, data centers, and underground infrastructure. Certified to IEC 60076-11 with F1 fire-behavior, C2 climatic resistance, and E2 environmental resilience, delivering void-free vacuum casting and partial discharge < 10 pC.

50–3150
kVA range
11 kV / 0.4 kV
voltage class
< 10 pC
partial discharge
F1 / C2 / E2
IEC 60076-11

Product Range

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — 19 Models Available

Standard and custom capacities available for global utility, industrial, and commercial projects. View complete catalog →

Technical Overview

11kV Cast Resin — Safe, Flame-Retardant & Maintenance-Free

Cast resin dry-type transformers eliminate oil leakage and fire hazards, making 11kV dry-type units the mandatory choice for indoor urban substations, shopping malls, hospitals, and offshore platforms. XinHuan utilizes high-grade vacuum epoxy casting technology with quartz filler, ensuring high mechanical short-circuit withstand and moisture resistance.

Both high-voltage (11kV) and low-voltage (0.4kV) windings are wound with electrolytic copper or aluminum foil and encapsulated under high vacuum (<1 mbar). The glass fiber reinforced solid insulation prevents insulation breakdown and resists thermal aging up to Class F (155°C) or Class H (180°C).

Each unit comes equipped with PT100 temperature sensors embedded in every LV phase winding, connected to a digital temperature controller (BWDK series) with automatic cooling fan control, over-temperature alarm, and trip contacts. IP20, IP23, or IP54 enclosures with safety interlocks are available.

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — Key Specifications

  • Rated HV Voltage

    11 kV (10 kV / 10.5 kV / 11.5 kV / 12 kV options)

  • Rated LV Voltage

    0.4 kV / 0.415 kV / 0.433 kV / 0.69 kV

  • Capacity Range

    50 kVA – 3150 kVA (Three Phase 50Hz / 60Hz)

  • Insulation Class

    Class F (155°C) / Class H (180°C)

  • Partial Discharge

    < 10 pC (tested per IEC 60076-11)

  • Environmental / Fire Class

    E2 (Environmental), C2 (Climatic), F1 (Fire Behaviour)

  • Temperature Rise Limit

    100K (Class F) / 125K (Class H)

  • Enclosure Protection

    IP00 (Core & Coil), IP20, IP23 (Outdoor / Drip-Proof), IP54

IEC / IEEE Reference Data

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — Standard Capacity & Loss Parameters

Request Custom Datasheet
11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — Standard Capacity (kVA), No-Load Loss (P0), Load Loss (Pk), Impedance (Uk%), and Weight Specification Table
Rated Capacity Voltage Ratio (HV / LV) No-Load Loss (P0) Load Loss (Pk) Impedance (Uk%) No-Load Current (I0%) Approx. Total Weight
50 kVA 11 / 0.415 kV 260 W 1,080 W 4.0% 1.3% 420 kg
100 kVA 11 / 0.415 kV 370 W 1,570 W 4.0% 1.1% 610 kg
160 kVA 11 / 0.415 kV 500 W 2,130 W 4.0% 1.0% 830 kg
200 kVA 11 / 0.415 kV 580 W 2,480 W 4.0% 0.9% 950 kg
250 kVA 11 / 0.415 kV 670 W 2,760 W 4.0% 0.8% 1,120 kg
315 kVA 11 / 0.415 kV 810 W 3,410 W 4.0% 0.8% 1,340 kg
400 kVA 11 / 0.415 kV 980 W 3,990 W 4.0% 0.7% 1,620 kg
500 kVA 11 / 0.415 kV 1,160 W 4,880 W 4.0% 0.7% 1,890 kg
630 kVA 11 / 0.415 kV 1,340 W 5,880 W 4.5% 0.6% 2,280 kg
800 kVA 11 / 0.415 kV 1,520 W 6,960 W 4.5% 0.6% 2,750 kg
1000 kVA 11 / 0.415 kV 1,770 W 8,130 W 6.0% 0.5% 3,350 kg
1250 kVA 11 / 0.415 kV 2,090 W 9,690 W 6.0% 0.5% 3,950 kg
1600 kVA 11 / 0.415 kV 2,450 W 11,730 W 6.0% 0.5% 4,800 kg
2000 kVA 11 / 0.415 kV 3,050 W 14,400 W 6.0% 0.5% 5,850 kg
2500 kVA 11 / 0.415 kV 3,850 W 18,200 W 6.0% 0.5% 6,800 kg

Guaranteed parameters based on standard factory testing. Custom loss levels (Tier-2 Ecodesign, DOE 2016, and high-efficiency low-noise designs) are engineered on request.

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — 3D Engineering Anatomy Cutaway

High-precision 3D component breakdown of 11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) illustrating CRGO silicon steel core assembly, electrolytic copper windings, insulation, and protection accessories.

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) internal 3D cutaway showing silicon steel core, copper windings, and tap changer
11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — Internal Core, Winding & Dielectric Assembly
High-Grade Silicon Core
Electrolytic Copper Coil
Off-Circuit / OLTC Tap Switch
Buchholz & Temp Relays

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — Factory Acceptance Testing (FAT)

Watch routine factory testing and quality control inspections inside XinHuan's manufacturing facility.

100% full routine tests (IEC 60076) conducted before export packing.

Engineering Submittal & Layout Workbench

Substation Room Fit & Multi-Equipment CAD Footprints

Select your equipment type and capacity to inspect verified GA engineering CAD line drawings, Single Line Diagrams (SLD), dimensions (L × W × H), roller gauge, and submittal clearances before procurement.

Available Ratings:
IEC 60076-1 Submittal Specs
XinHuan Engineering GA CAD Drawing
XinHuan Engineering Single Line Diagram (SLD)
11kV / 33kV Dual Voltage
IEC 60076 / IEEE Compliant
100% Routine Factory Tested
Export Nitrogen / Seaworthy Pack

1000 kVA Technical Dimensions

IEC 60076-1

International utility & industrial submittal specifications

Overall Length (L) 1,750 mm
Overall Width (W) 1,120 mm
Overall Height (H) 1,780 mm
Roller Wheel Track Gauge (D) 820 mm
Total Equipment Net Weight 3,820 kg
Min Substation Clearance 1,000 mm surrounding
Rated Voltage / System 11 kV / 33 kV Dual Primary
Applicable Standard IEC 60076-1 / IEEE C57
Download Technical Data Sheet (PDF) Request Factory Engineering Submittal Package

Full CAD DXF/DWG vector footprints, 3D STEP models, and custom project submittals provided within 2 hours upon request.

Quality & Compliance

Certified B2B Manufacturing & Laboratory Performance

Every transformer, compact substation, and switchgear unit is engineered under audited ISO quality management systems and type-tested according to IEC 60076 and ANSI C57 international standards.

IAF / CNAS Accredited

ISO 9001:2015 Quality System

Certified Quality Management System covering design, coil winding, vacuum drying, oil filling, and routine testing of 10kV–35kV distribution transformers.

Environmental System

ISO 14001:2015 Environmental

Environmental Management System certifying low-loss eco-designed core assemblies, zero PCB insulation oil, and environmentally safe production controls.

Occupational Health

ISO 45001:2018 Safety System

Occupational Health and Safety Management System ensuring safety containment in high-voltage testing bays and factory assembly protocols.

CNAS Lab Type Tests

IEC 60076 & GB Type Tests

Complete routine and type test records (temperature rise, impulse voltage withstand, short-circuit withstand) conducted at CNAS-accredited national research institutes.

SGS Audited Supplier

SGS Verified Manufacturer Audit

On-site factory audit certificate by SGS / Made-in-China, verifying manufacturing premises, export capacity, assembly lines, and legal qualification.

≥180 Units/Yr Export

International Delivery Certificate

Verified annual supply performance and delivery certificate for overseas power grid EPC and industrial infrastructure projects (Mozambique, Nigeria, Kenya, SEA).

Technical Q&A

Frequently Asked Questions — 11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14)

Class F1 certifies fire behavior: self-extinguishing within seconds after removal of external flame, with zero emission of halogen or toxic smoke. Class C2 certifies climatic resistance: safe storage, transport, and energization down to -25°C without resin cracking. Class E2 certifies environmental performance: resistance to heavy humidity (>93%) and severe atmospheric pollution.

Every unit undergoes partial discharge routine testing per IEC 60076-11 clause 14.3. Thanks to void-free vacuum casting under <1 mbar with micro-silica powder filler, our partial discharge level is strictly guaranteed below 10 pC at 1.3×Um (far superior to the standard IEC 60076-11 limit of ≤20 pC).

By installing cross-flow cooling fans beneath the cast coils and linking them to the digital temperature controller, continuous transformer capacity is boosted by +40% to +50% without damaging the Class F (155°C) or Class H (180°C) insulation. This provides crucial emergency peak headroom during summer or industrial surges.

Three high-precision PT100 platinum RTD sensors are embedded directly into the hot-spot of each low-voltage phase winding. They connect to a digital temperature controller (BWDK series) providing real-time LED temperature display, automatic cooling fan start/stop, over-temperature alarm contacts, and trip contacts.

IP00 is the core-and-coil bare assembly for installation inside clean switchgear cubicles. IP20 prevents ingress of fingers or solid objects >12mm for indoor electrical rooms. IP23 adds louvers to prevent water drops falling at up to 60° angle. IP54 sealed outdoor enclosures with air-to-air heat exchangers are available for coastal or dusty environments.

Yes. The epoxy resin completely encapsulates both primary and secondary windings in a solid impervious dielectric monolith. Unlike VPI open-ventilated dry transformers, cast resin units suffer zero degradation from 100% relative humidity, salt mist, or fungus, and require no pre-drying before energization after prolonged shutdown.

SCB14 series reduces no-load idle losses by 15-20% and load losses by 10% compared to legacy SCB11 models. In continuous 24/7 commercial, hospital, or data center operation, the cumulative electricity savings pay back the modest initial price premium within 2.5 to 3.5 years.

Please specify: kVA capacity (50 kVA to 2500 kVA), HV/LV voltage (e.g. 11kV / 0.415kV), conductor material (copper or aluminum), enclosure requirement (IP00 core-and-coil, IP20, or IP23), frequency (50Hz or 60Hz), and destination seaport for an authoritative CIF or FOB proposal in 24 hours.

Engineering Reference Silo

Transformer Category Pillars & International Standards

China Transformer Manufacturer Export Hub

11kV Dry-Type Cast Resin Transformers (SCB13 / SCB14) — Direct Factory Quotation

Request Engineering Submittals & Price

Include capacity (kVA), capacity in kVA, primary voltage (11kV), enclosure type (IP00/IP20/IP23), copper or aluminum winding, destination port, and required quantity. Our engineers respond with certified data sheets within 24 hours.